or Select from map
ID#: Station ID: Valid: Variable: Final Value: Adjustment:
Air Temperature [F]
9744AIO26 Nov 2024, 12:00 AMtmpf21.20.2
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 25.3 STD Temp 25.5 Awos Dew 21.2 STD Dew 20.0 [FYI Check Made]
9550AIO23 Aug 2023, 12:00 AMtmpf78.1-0.1
Comments: Arrived on site awos ok except Temp/Dew Change out temp probe from inventory Completed change Verified working Used part # 5190-F from inventory Awos Temp 93.1 STD Temp 93.0 Awos Dew 78.1 STD Dew 78.2 [FYI Check Made]
9524AIO12 Jul 2023, 12:00 AMtmpf69.9-0.1
Comments: Started annual inspection Completed inspection Awos verified Awos Temp 80.1 STD Temp 80.0 Awos Dew 69.9 STD Dew 69.3 [FYI Check Made]
9426AIO15 Mar 2023, 12:00 AMtmpf32-0.1
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 38.8 STD Temp 38.7 Awos Dew 32.0 STD Dew 29.2 [FYI Check Made]
9364AIO06 Dec 2022, 12:00 AMtmpf22.30.6
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 30.1 STD Temp 30.7 Awos Dew 22.3 STD Dew 20.2 [FYI Check Made]
9264AIO15 Mar 2022, 12:00 AMtmpf35.2-0.1
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 57.0 Std Temp 56.9 Awos Dew 35.2 Std Dew 32.2 [FYI Check Made]
9152AIO16 Nov 2021, 12:00 AMtmpf46.80.1
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Departed site Awos Temp 62.2 std temp 62.3 Awos Dew 46.8 std dew 45.5 [FYI Check Made]
9102AIO26 Aug 2021, 12:00 AMtmpf73.3-0.1
Comments: started inspection wiht FAA Found North marker needed replacement fan for CDP cabinet AWOS verified AWOS temp 73.3/Standard 73.2 AWOS dew 73.3/Standard 71.2 [FYI Check Made]
8994AIO11 Mar 2021, 12:00 AMtmpf29.30.4
Comments: tri annual inspection completed, no issues found Awos temp 47.2/Standard 47.6 Awos dew 29.3/Standard 29.7 [FYI Check Made]
8936AIO31 Dec 2020, 12:00 AMtmpf14.40.5
Comments: initial temp and humidity readings out of tolerance; replaced sensor AWOS temp 20.4/Standard 20.9 AWOS dewpoint 14.4/Standard 15.1 [FYI Check Made]
8844AIO06 Jul 2020, 12:00 AMtmpf731.2
Comments: AWOS verified except present weather sensor, found bad temp readings from sensor. Will follow up for options AWOS temp 84.2/Standard 85.4 AWOS dew 73.0/Standard 71.4 Sprayed around AWOS [FYI Check Made]
8794AIO29 Jan 2020, 12:00 AMtmpf27.50
Comments: Temp Awos 29.2 /29.2 Standard Dew Awos 27.5 / 25.3 Standard No issues found [FYI Check Made]
8648AIO14 May 2019, 12:00 AMtmpf60.80.1
Comments: Temp Awos 74.1/74.2 standard Dew Awos 60.8/60.3 Standard Found Present weather Temp probe is bad. Believe Sensor may need to go in for repair.  Will Check if I am correct. [FYI Check Made]
8584AIO22 Feb 2019, 12:00 AMtmpf18.2-1
Comments: Temp Awos 28.8/27.8 Standard Dew Awos 18.2/17.3 Standard [FYI Check Made]
8530AIO31 Oct 2018, 12:00 AMtmpf39.9-0.7
Comments: Temp Awos 56.3/ 55.6 Standard Dew Awos 39.9/ 37.7 Standard All good but problem on present weather is bad will have issues in the winter. [FYI Check Made]
2116AIO12 Sep 2017, 12:00 AMtmpf81.90.6
Comments: PM performed. AWOS t/d: 81.3/60.4 Std. t/d: 81.9/58.1
1867AIO04 Jan 2017, 12:00 AMtmpf12.2-1.2
Comments: Check T/DP: AWOS 13.4/-4.0 Std. 12.2/-3.7
1725AIO27 Jan 2016, 12:00 AMtmpf26.7-0.9
Comments: Check T/DP: AWOS 27.6/25.3 Std. 26.7/23.1
1647AIO29 Sep 2015, 12:00 AMtmpf66-0.3
Comments: Check T/DP: AWOS 66.3/49.8 Std. 66.0/49.9
1522AIO19 May 2015, 12:00 AMtmpf51.2-0.5
Comments: Calibrated T/DP: AWOS 51.7/37.6 Std. 51.2/36.7
1472AIO10 Mar 2015, 12:00 AMtmpf64.60.23
Comments: Calibrate T/DP: AWOS 64.37/36.5 Std. 64.6/36.8 Replace Keyboard due to bad Mouse.
1375AIO20 Nov 2014, 12:00 AMtmpf23.80.2
Comments: Calibrate T/DP: AWOS 23.6/13.5 Std. 23.8/14.6
1349AIO17 Sep 2014, 12:00 AMtmpf67.9-1
Comments: Calibrate T/DP: AWOS 68.9/59.3 Std. 67.9/58.8 Spray Roundup
1116AIO09 Jan 2014, 12:00 AMtmpf16.3-0.3
Comments: Calibrate T/DP: AWOS 16.6/13.1 Std. 16.3/13.7
932AIO20 Sep 2013, 12:00 AMtmpf64.8-0.5
Comments: Calibrate T/DP: AWOS 65.3/49.1 Std. 64.8/48.9
204AIO07 Nov 2006, 12:10 PMtmpf651
Comments: Reported by AWOS Contractor.
150AIO14 Feb 2006, 02:50 PMtmpf64-1.5
Comments: Reported by AWOS Contractor.
71AIO15 Apr 2005, 11:00 AMtmpf652
Comments: Reported by AWOS Contractor.
29AIO14 Nov 2004, 09:20 AMtmpf362
Comments: Reported by AWOS Contractor.
Dew Point [F]
9745AIO26 Nov 2024, 12:00 AMdwpf20-1.2
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 25.3 STD Temp 25.5 Awos Dew 21.2 STD Dew 20.0 [FYI Check Made]
9551AIO23 Aug 2023, 12:00 AMdwpf78.20.1
Comments: Arrived on site awos ok except Temp/Dew Change out temp probe from inventory Completed change Verified working Used part # 5190-F from inventory Awos Temp 93.1 STD Temp 93.0 Awos Dew 78.1 STD Dew 78.2 [FYI Check Made]
9525AIO12 Jul 2023, 12:00 AMdwpf69.3-0.6
Comments: Started annual inspection Completed inspection Awos verified Awos Temp 80.1 STD Temp 80.0 Awos Dew 69.9 STD Dew 69.3 [FYI Check Made]
9427AIO15 Mar 2023, 12:00 AMdwpf29.2-2.8
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 38.8 STD Temp 38.7 Awos Dew 32.0 STD Dew 29.2 [FYI Check Made]
9365AIO06 Dec 2022, 12:00 AMdwpf20.2-2.1
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 30.1 STD Temp 30.7 Awos Dew 22.3 STD Dew 20.2 [FYI Check Made]
9265AIO15 Mar 2022, 12:00 AMdwpf32.2-3
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Awos Temp 57.0 Std Temp 56.9 Awos Dew 35.2 Std Dew 32.2 [FYI Check Made]
9153AIO16 Nov 2021, 12:00 AMdwpf45.5-1.3
Comments: Arrived on site awos ok Started tri annual inspection Completed inspection Awos verified Departed site Awos Temp 62.2 std temp 62.3 Awos Dew 46.8 std dew 45.5 [FYI Check Made]
9103AIO26 Aug 2021, 12:00 AMdwpf71.2-2.1
Comments: started inspection wiht FAA Found North marker needed replacement fan for CDP cabinet AWOS verified AWOS temp 73.3/Standard 73.2 AWOS dew 73.3/Standard 71.2 [FYI Check Made]
8995AIO11 Mar 2021, 12:00 AMdwpf29.70.4
Comments: tri annual inspection completed, no issues found Awos temp 47.2/Standard 47.6 Awos dew 29.3/Standard 29.7 [FYI Check Made]
8937AIO31 Dec 2020, 12:00 AMdwpf15.10.7
Comments: initial temp and humidity readings out of tolerance; replaced sensor AWOS temp 20.4/Standard 20.9 AWOS dewpoint 14.4/Standard 15.1 [FYI Check Made]
8845AIO06 Jul 2020, 12:00 AMdwpf71.4-1.6
Comments: AWOS verified except present weather sensor, found bad temp readings from sensor. Will follow up for options AWOS temp 84.2/Standard 85.4 AWOS dew 73.0/Standard 71.4 Sprayed around AWOS [FYI Check Made]
8795AIO29 Jan 2020, 12:00 AMdwpf25.3-2.2
Comments: Temp Awos 29.2 /29.2 Standard Dew Awos 27.5 / 25.3 Standard No issues found [FYI Check Made]
8649AIO14 May 2019, 12:00 AMdwpf60.3-0.5
Comments: Temp Awos 74.1/74.2 standard Dew Awos 60.8/60.3 Standard Found Present weather Temp probe is bad. Believe Sensor may need to go in for repair.  Will Check if I am correct. [FYI Check Made]
8585AIO22 Feb 2019, 12:00 AMdwpf17.3-0.9
Comments: Temp Awos 28.8/27.8 Standard Dew Awos 18.2/17.3 Standard [FYI Check Made]
8531AIO31 Oct 2018, 12:00 AMdwpf37.7-2.2
Comments: Temp Awos 56.3/ 55.6 Standard Dew Awos 39.9/ 37.7 Standard All good but problem on present weather is bad will have issues in the winter. [FYI Check Made]
2117AIO12 Sep 2017, 12:00 AMdwpf58.1-2.3
Comments: PM performed. AWOS t/d: 81.3/60.4 Std. t/d: 81.9/58.1
1868AIO04 Jan 2017, 12:00 AMdwpf-3.70.3
Comments: Check T/DP: AWOS 13.4/-4.0 Std. 12.2/-3.7
1726AIO27 Jan 2016, 12:00 AMdwpf23.1-2.2
Comments: Check T/DP: AWOS 27.6/25.3 Std. 26.7/23.1
1648AIO29 Sep 2015, 12:00 AMdwpf49.90.1
Comments: Check T/DP: AWOS 66.3/49.8 Std. 66.0/49.9
1523AIO19 May 2015, 12:00 AMdwpf36.7-0.9
Comments: Calibrated T/DP: AWOS 51.7/37.6 Std. 51.2/36.7
1473AIO10 Mar 2015, 12:00 AMdwpf36.80.3
Comments: Calibrate T/DP: AWOS 64.37/36.5 Std. 64.6/36.8 Replace Keyboard due to bad Mouse.
1376AIO20 Nov 2014, 12:00 AMdwpf14.61.1
Comments: Calibrate T/DP: AWOS 23.6/13.5 Std. 23.8/14.6
1350AIO17 Sep 2014, 12:00 AMdwpf58.8-0.5
Comments: Calibrate T/DP: AWOS 68.9/59.3 Std. 67.9/58.8 Spray Roundup
1117AIO09 Jan 2014, 12:00 AMdwpf13.70.6
Comments: Calibrate T/DP: AWOS 16.6/13.1 Std. 16.3/13.7
933AIO20 Sep 2013, 12:00 AMdwpf48.9-0.2
Comments: Calibrate T/DP: AWOS 65.3/49.1 Std. 64.8/48.9
104AIO18 May 2005, 01:13 PMdwpf60-3
Comments: Reported by AWOS Contractor.
72AIO15 Apr 2005, 11:00 AMdwpf45-1
Comments: Reported by AWOS Contractor.
30AIO14 Nov 2004, 09:20 AMdwpf31-4
Comments: Reported by AWOS Contractor.